Satpur MIDC, Nashik, Maharashtra
OEM Factory Direct
OEM Manufacturer • Satpur MIDC, Nashik

Reliable Power.
Smarter Engineering.

Shiv Electronics manufactures dependable, industrial-grade power electronics and electrical systems. From high-capacity 3-phase lift backup UPS and ARDs to servo stabilizers, SMPS, and custom sheet-metal enclosures — engineered for zero downtime.

6 – 100 kVA Lift UPS Capacity Range
DSP & IGBT Microprocessor Pure Sine Wave
100% In-House Sheet Metal & Electronics QA
Shiv Electronics 3-Phase Lift Backup Inverter System
FLAGSHIP ELEVATOR SOLUTION

Offline UPS for Lifts

Heavy-duty 3 Phase In / 3 Phase Out engineered for regenerative elevator motor loads.

415V ±15% Input Pure Sine Wave CCCV Charger 110% Overload 8s
OEM Customized Custom Enclosure & Sizing
ABOUT SHIV ELECTRONICS

Engineering solutions built for dependable industrial performance.

Shiv Electronics is an established OEM power-electronics manufacturing facility situated in the industrial corridor of Satpur MIDC, Nashik, Maharashtra.

Founded under the technical leadership of Sunil Pagar (Managing Director) and Shivam Pagar (Manager), we specialize in end-to-end design, component assembly, testing, and sheet-metal enclosure fabrication for critical electrical power applications.

DSP-Based Inverter Architecture

Digital Signal Processor control provides precise frequency and low harmonic distortion.

In-House Sheet Metal Fabrication

Precision CNC cutting, bending, and protective powder coating for durable enclosures.

High Overload & Surge Tolerance

Handles initial motor inrush currents up to 300% without nuisance tripping.

Satpur MIDC Direct Support

Immediate access to genuine spare parts, engineering revisions, and factory technicians.

Discuss OEM Requirements

Manufacturing Profile

Manufacturing Model OEM & Custom Built
Plant Location Satpur MIDC, Nashik
Core Specialization Power Electronics & Lift Backup
Testing Standards 100% Full-Load Burn-In
Elevator OEM Partnering:

We manufacture custom-dimension backup systems, ARD units, and control enclosures tailored for leading elevator manufacturers, contractors, and real-estate developers.

OUR PRODUCT RANGE

Heavy-Duty Power & Electrical Solutions

Designed, fabricated, and rigorously tested in Satpur MIDC, Nashik. Explore our comprehensive range of power electronics built for industrial stability.

Online UPS Component assets/online-ups.jpg
Zero Transfer Time

Online UPS

True double-conversion online UPS providing continuous, clean, and isolated power for mission-critical IT servers, hospital ICUs, and automated manufacturing lines.

  • Zero Transfer Time (0 ms interruption)
  • Galvanic Isolation Transformer options
  • Up to 95% operating efficiency
ARD for Lift Component assets/ard-lift.jpg
Elevator Life Safety

ARD for Lift (Rescue Device)

Automatic Rescue Device (ARD) that intelligently senses grid failure, moves the elevator cab in the lightest load direction to the nearest floor, and opens doors safely.

  • Fully automatic micro-controller sensing
  • Preserves cabin lighting and ventilation
  • Float charging system for long battery life
Voltage Stabilizer Component assets/stabilizer.jpg
Precision Regulation

Industrial Voltage Stabilizer

Servo and static automatic voltage stabilizers built for extreme voltage fluctuations in industrial belts. Protects CNC tooling, chillers, and printing presses.

  • Balanced & Unbalanced 3-Phase regulation
  • Tight ±1% voltage accuracy
  • Fast correction speed up to 35 V/sec
SMPS Component assets/smps.jpg
DC Conversion

Switched Mode Power Supply (SMPS)

High-efficiency, compact AC-to-DC power supplies engineered for industrial automation panels, PLC controllers, sensors, and telecom cabinets.

  • 12V, 24V, and 48V DC outputs
  • DIN-rail & chassis mount chassis
  • Overload & short circuit auto-recovery
Industrial Battery Charger Component assets/battery-charger.jpg
CCCV Charging

Industrial Battery Charger

Heavy-duty Constant Current Constant Voltage (CCCV) battery charging systems for tubular, lead-acid, and SMF battery banks in substations and backup systems.

  • 24V to 360V DC multi-voltage configurations
  • Auto Boost and Float charging modes
  • Reverse polarity & overcharge protection
Energy Saver Component assets/energy-saver.jpg
Power Quality

Industrial Energy Saver

Engineered power factor correction and energy optimization units that reduce maximum demand penalties, lower harmonic losses, and optimize utility billing.

  • Power factor target maintained near 0.99
  • Microcontroller automatic step control
  • Harmonic attenuation filtering
Regulated DC Power Supply Component assets/dc-power-supply.jpg
Stable DC

Regulated DC Power Supply

Precision-regulated linear and SMPS DC power sources designed for test benches, R&D laboratories, burn-in racks, and electronic production environments.

  • Line & load regulation < 0.05%
  • Ultra-low ripple and electrical noise
  • Dual digital meters for Volts and Amps
Sheet Metal Fabrication Component assets/sheet-metal-fab.jpg
In-House Manufacturing

Sheet Metal Fabrication & Enclosures

Custom control cabinets, battery racks, and UPS enclosures fabricated using CNC laser cutting, press-brake bending, and durable anti-corrosion powder coating.

  • High-grade CRCA sheet metal (1.2mm–3.0mm)
  • IP42 to IP55 enclosure protection
  • Custom ventilation & OEM branding
OFFICIAL PRODUCT SPECIFICATION SHEET

Offline UPS for Lift — 3 Phase Input / 3 Phase Output

Manufactured in accordance with Shiv Electronics engineering design benchmarks. Engineered with DSP-based IGBT technology, Pure Sine Wave output, and CCCV battery charging for 6 kVA through 100 kVA elevator backup installations.

Input: 415 V AC ± 15% (3-Phase) Output: 400 / 415 V AC Pure Sine Wave Efficiency Up to 95% Continuous Duty Cycle
Formatted for engineering approvals
Select Rating to Inspect Specifications (6 kVA – 100 kVA):
Swipe horizontally to choose rating
Rating Selected
15 kVA
DC Bus Voltage
180 V DC (15 Batt)
Typical Lift Motor
Up to 12.5 HP (9.3 kW)
Passenger Capacity
10 – 13 Passengers
Specification Parameter 6 kVA 8 kVA 10 kVA 15 kVA 20 kVA 30 kVA 40 kVA 50 kVA 60 kVA 75 kVA 100 kVA
DC Bus Voltage 72 V 96 V 144 V 180 V 240 V 360 V 360 V 360 V 360 V 360 V 360 V
Battery Bank (12V Units) 6 Nos. 8 Nos. 12 Nos. 15 Nos. 20 Nos. 30 Nos. 30 Nos. 30 Nos. 30 Nos. 30 Nos. 30 Nos.
Mains Input Voltage 415 V AC ± 15% (3 Phase, 4 Wire)
Input Mains Frequency 50 Hz ± 4 Hz
Battery Charger Architecture CCCV (Constant Current Constant Voltage type charging algorithm)
Typical Lift Motor Suitability Up to 5 HP Up to 7.5 HP Up to 10 HP Up to 12.5 HP Up to 15 HP Up to 25 HP Up to 35 HP Up to 40 HP Up to 50 HP Up to 60 HP Up to 75 HP+
Manual Changeover Provision Optional Optional Provided as Standard Built-in (> 10 kVA)

Inverter Mode Technical Parameters

TechnologyDSP based IGBT Technology
Output Voltage400 / 415 V AC, 3 Phase
Output Frequency50 Hz ± 0.1 Hz
Output WaveformPure Sine Wave
Harmonic DistortionLess than 3% on Linear Load
Inverter EfficiencyUp to 90% / 92% / 95% (Nominal load)
Power Factor0.8
Overload Capability110% for 8 seconds
Crest Factor3 : 1 (High inrush tolerance)
Audible NoiseLess than 65 dB at 1 Meter
Duty CycleContinuous 24x7 Rated

Environmental & Thermal Compliance

Operating Ambient0°C to 45°C
Relative HumidityMax 95% non-condensing
Cooling SystemForced Air Cooling with high-velocity industrial fans
Enclosure MaterialHeavy-gauge CRCA sheet metal with powder coating
Cable TerminationHeavy-duty terminal blocks with safety shroud
Grid CompatibilitySuitable for unstable Indian grid and DG set synchrony

8-Point Comprehensive Safety & Protection Suite

Output Under & Over Voltage Guards elevator control boards and motors from dangerous voltage swings.
Short-Circuit Protection Instant electronic and fuse-based isolation to prevent semiconductor damage.
Input Under & Over Voltage Seamlessly switches between mains conditioning and battery backup safely.
Over Temperature Cutoff Thermal sensors trip the system if internal heatsinks exceed safe operating limits.
Output Overload Protection Allows 110% overload for 8 seconds to support elevator motor startup.
DC Under & Over Voltage Prevents deep battery discharge and high charging terminal voltage stress.
Phase Reverse Protection Ensures correct 3-phase rotational sequence for elevator traction motors.
Surge & Spike Suppression Absorbs lightning-induced voltage surges and industrial inductive spikes.

Digital LCD Display Readout

Display TypeDigital Multi-Parameter LCD Display
Input MonitoringMains R-Y-B Line Voltages and Frequency
Output MonitoringOutput R-Y-B Phase Voltages and Current Draw
Battery MetricsReal-time DC Battery Voltage and Charge Status
Load FactorPercentage Load Capacity Utilization (%)
Fault DiagnosticsDirect error codes for overload, phase imbalance, thermal trip

Indications, Alarms & Changeover

Mains On LED Indication
Inverter On LED Indication
Battery Low LED & Audible Buzzer Alarm
Fault Status LED & Audible Buzzer Alarm
Overload Alert LED & Audible Buzzer Alarm
Over Temperature LCD Alert & Intermittent Buzzer

Changeover Capability: Manual changeover switch is optional for 6 kVA and 8 kVA models; provided built-in as standard for all models above 10 kVA.

OUR PRODUCTION WORKFLOW

Built with an In-House Manufacturing Mindset

From raw sheet metal and PCB assembly to final load testing in Satpur MIDC, our 4-stage engineering pipeline ensures zero compromise on quality.

01

Engineering Sizing & Design

We evaluate your elevator motor ratings, starting peak currents, and building backup duration to specify the exact kVA and battery DC bus.

02

CNC Sheet Metal & Enclosure

In-house CNC laser cutting, bending, and 7-tank powder-coating fabricate rugged cabinets dimensioned precisely for elevator machine rooms.

03

DSP & IGBT Assembly

Advanced digital signal processors, heavy-duty IGBT switches, copper wound isolation transformers, and CCCV battery chargers are integrated.

04

Full-Load Testing & Dispatch

Every unit undergoes continuous 100% full-load burn-in, inductive surge simulation, and safety trip calibration before factory dispatch.

APPLICATIONS

Serving Critical Electrical Sectors

Our systems provide continuous power protection across high-stake commercial, residential, and industrial facilities throughout Maharashtra and India.

Elevator OEMs & Contractors

Dedicated lift backup inverters, ARDs, and control cabinets customized for lift manufacturers.

Hospitals & Healthcare

Clean sine wave power for diagnostic MRI, CT scans, ICU monitoring, and surgical operation theaters.

IT, Data Centers & Telecom

Zero-transfer double conversion online UPS systems protecting sensitive network servers and switches.

CNC & Manufacturing Plants

Servo voltage regulators and heavy-duty DC power supplies shielding CNC machinery from grid surges.

THE OEM ADVANTAGE

Why Industry Leaders Choose Shiv Electronics

We bridge the gap between heavy-duty electrical engineering and tailored customer support directly from Satpur MIDC, Nashik.

OEM Manufacturing Expertise

Decades of collective experience designing power electronics tailored to withstand harsh Indian electrical grid variations.

Complete 6–100 kVA Portfolio

From residential 4-passenger lifts to high-speed commercial glass towers and heavy freight elevators, we have proven sizing models.

Custom Fabrication & Branding

Custom enclosure dimensions, private label branding, and custom terminal layouts specifically designed for elevator OEMs.

Direct Local MIDC Support

Direct communication with Managing Director Sunil Pagar and Manager Shivam Pagar for fast quote dispatch, technical consults, and spares.

FREQUENT QUESTIONS

Frequently Asked Questions

Answers to common queries regarding our lift backup UPS systems, OEM branding, and technical specifications.

The sizing depends on the lift motor HP/kW rating, passenger capacity (e.g. 6 passenger vs 13 passenger stretcher lift), and motor drive technology (VVVF variable frequency vs direct on-line). For instance, a standard 6-passenger lift with a 5 HP motor pairs seamlessly with our 6 kVA or 8 kVA unit, while high-rise 10–13 passenger lifts typically require 15 kVA to 20 kVA. You can consult our technical team directly at +91 9370796979 for precise load calculations.
An ARD (Automatic Rescue Device) operates strictly as an emergency rescue mechanism: it moves the stranded lift to the nearest landing floor, opens the doors to let passengers exit, and shuts down until power returns. A Lift Offline UPS, on the other hand, provides continuous uninterrupted 3-phase pure sine wave power, allowing the elevator to continue making multiple trips and full regular operation throughout an extended power blackout.
Yes. As a direct manufacturer with in-house CNC sheet metal fabrication and powder coating, we routinely manufacture systems with custom chassis dimensions to fit constrained elevator machine rooms. We also offer private label branding and custom electrical terminations for elevator OEMs and electrical contractor networks.
Our systems support tubular lead-acid, sealed maintenance-free (SMF/VRLA), and custom industrial battery banks. The DC bus voltages range from 72V DC (6 batteries) for 6 kVA models up to 360V DC (30 batteries) for 30 kVA to 100 kVA systems. The built-in Constant Current Constant Voltage (CCCV) charger ensures optimum battery longevity and thermal protection.
Our manufacturing facility is located in Satpur MIDC, Nashik, Maharashtra. You can fill out the inquiry form below, initiate a quick WhatsApp chat with Managing Director Sunil Pagar (+91 9370796979) or Manager Shivam Pagar (+91 8983994913), or email us at shivelectronicsnsk@gmail.com for same-day official proposals.
DIRECT FACTORY CONTACT

Let's discuss your power electronics requirement.

Get in touch with Shiv Electronics for project quotations, OEM partnerships, and customized power backup solutions. We respond promptly with technical data and competitive factory-direct pricing.

Sunil Pagar Managing Director • Commercial & OEM Partnerships
Shivam Pagar Manager • Technical Operations & Production
Manufacturing Plant & Works: Satpur MIDC, Nashik, Maharashtra, India
Official Email Address: shivelectronicsnsk@gmail.com
Operating Hours: Sunday – Friday: 9:00 AM – 7:30 PM (IST)

Request an OEM Quotation

Fill out your requirements below for engineering consultation or instant WhatsApp pricing.